Disclaimer:
Medidex is not a provider of medical services and all information is provided for the convenience of the user. No medical decisions should be made based on the information provided on this website without first consulting a licensed healthcare provider.This website is intended for persons 18 years or older. No person under 18 should consult this website without the permission of a parent or guardian.
Ultra-Technekow
Overview
What is Ultra-Technekow?
The Ultra-Technekow V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution.
This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation.
The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions.
Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration.
Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution.
What does Ultra-Technekow look like?













What are the available doses of Ultra-Technekow?
Sorry No records found.
What should I talk to my health care provider before I take Ultra-Technekow?
Sorry No records found
How should I use Ultra-Technekow?
The Ultra-Technekow™ V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits.
Sodium Pertechnetate Tc 99m is used as an agent for:
Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy)
Sodium Pertechnetate Tc 99m is used as an agent for:
Thyroid Imaging Urinary Bladder Imaging (direct isotopic cystography) for the detection of vesico-ureteral reflux
Sodium Pertechnetate Tc 99m is administered by intravenous injection. When imaging the nasolacrimal drainage system, instill the Sodium Pertechnetate Tc 99m by the use of a device such as a micropipette or similar method which will ensure the accuracy of the dose.
For imaging the urinary bladder and ureters (direct isotopic cystography), the Sodium Pertechnetate Tc 99m is administered by direct instillation aseptically into the bladder via a urethral catheter, following which the catheter is flushed with approximately 200 mL of sterile saline directly into the bladder.
The suggested dose ranges employed for various diagnostic indications in the average ADULT PATIENT (70 kg) are as follows:
Vesico-ureteral imaging: 18.5 to 37 MBq (0.5 to 1 mCi)Thyroid gland imaging: 37 to 370 MBq (1 to 10 mCi)Salivary gland imaging: 37 to 185 MBq (1 to 5 mCi)Nasolacrimal drainage system: Maximum dose of 3.7 MBq (100 µCi)
The recommended dosages in PEDIATRIC PATIENTS are:
Vesico-ureteral imaging: 18.5 to 37 MBq (0.5 to 1 mCi)Thyroid gland imaging: 2.22 to 2.96 MBq (60 to 80 µCi) per kg body weight
The patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration.
Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit. If the solution is discolored, discontinue use of the generator immediately. The solution to be administered as the patient dose should be clear, colorless, and contain no particulate matter.
What interacts with Ultra-Technekow?
None.
What are the warnings of Ultra-Technekow?
Considering the potential risk of developing Reye's syndrome, salicylate products should not be administered to children or teenagers with varicella or influenza, unless directed by a physician.
Radiation risks associated with the use of Sodium Pertechnetate Tc 99m are greater in pediatric patients than in adults and, in general, the younger the patient the greater the risk owing to greater absorbed radiation doses and longer life expectancy. These greater risks should be taken firmly into account in all benefit risk assessments involving pediatric patients.
Long-term cumulative radiation exposure may be associated with an increased risk of cancer.
Only use generator eluant specified for use with the Ultra-Technekow V4 Generator. Do not use any other generator eluant or saline from any other source.
What are the precautions of Ultra-Technekow?
Radiopharmaceuticals should be used only by physicians who are qualified by training and experience in the safe use and handling of radionuclides and whose experience and training have been approved by the appropriate government agency authorized to license the use of radionuclides.
As in the use of any radioactive material, care should be taken to minimize radiation exposure to the patient consistent with proper patient management and to ensure minimum radiation exposure to occupational workers.
After the termination of the nasolacrimal imaging procedure, blowing the nose and washing the eyes with sterile distilled water or an isotonic sodium chloride solution will further minimize the radiation dose.
Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from time of generator elution.
Carcinogenesis, Mutagenesis, Impairment of Fertility
No long-term animal studies have been performed to evaluate carcinogenic or mutagenic potential or whether Sodium Pertechnetate Tc 99m may affect fertility in males or females.
Pregnancy Category C
In animal reproductive studies, Sodium Pertechnetate Tc 99m (as free pertechnetate) has been shown to cross the placental barrier. It is not known whether Sodium Pertechnetate Tc 99m can cause fetal harm when administered to a pregnant woman or can affect reproductive capacity.
Sodium Pertechnetate Tc 99m should be given to pregnant women only if the expected benefits to be gained clearly outweigh the potential hazards.
Ideally, examinations using radiopharmaceutical drug products - especially those elective in nature - of women of childbearing capability should be performed during the first ten days following the onset of menses.
Nursing Mothers
Technetium Tc-99m is excreted in human milk during lactation, therefore, formula-feedings should be substituted for breast-feedings.
Pediatric Use
See and sections. Also see the description of additional risk under .
What are the side effects of Ultra-Technekow?
Allergic reactions including anaphylaxis have been reported infrequently following the administration of Sodium Pertechnetate Tc 99m.
What should I look out for while using Ultra-Technekow?
None.
Radiation risks associated with the use of Sodium Pertechnetate Tc 99m are greater in pediatric patients than in adults and, in general, the younger the patient the greater the risk owing to greater absorbed radiation doses and longer life expectancy. These greater risks should be taken firmly into account in all benefit risk assessments involving pediatric patients.
Long-term cumulative radiation exposure may be associated with an increased risk of cancer.
Only use generator eluant specified for use with the Ultra-Technekow V4 Generator. Do not use any other generator eluant or saline from any other source.
What might happen if I take too much Ultra-Technekow?
Sorry No Records found
How should I store and handle Ultra-Technekow?
Store at 20° to 25°C (68 to 77°F);excursions permitted to 15° to 30° C (59° to 86°F) [See USP Controlled Room Temperature]. Protect from moisture. Dispense in tight, child-resistant container (USP).The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.The Ultra-Technekow V4 (Technetium Tc 99m) Generators contain the following amount of molybdenum Mo-99 at the date and time of calibration stated on the label.Catalog No.9010 37 gigabecquerels (1.0 curie) NDC 69945-010-039015 55.5 gigabecquerels (1.5 curies) NDC 69945-015-049020 74 gigabecquerels (2.0 curies) NDC 69945-020-059025 92.5 gigabecquerels (2.5 curies)NDC 69945-025-069030 111 gigabecquerels (3.0 curies)NDC 69945-030-079035 129.5 gigabecquerels (3.5 curies)NDC 69945-035-089051 185 gigabecquerels (5.0 curies)NDC 69945-051-099060 222 gigabecquerels (6.0 curies)NDC 69945-060-109075 277.5 gigabecquerels (7.5 curies)NDC 69945-075-119110 407 gigabecquerels (11.0 curies)NDC 69945-110-129140 518 gigabecquerels (14.0 curies)NDC 69945-140-139160 592 gigabecquerels (16.0 curies)NDC 69945-160-149190 703 gigabecquerels (19.0 curies)NDC 69945-190-15Each generator is supplied with the following components for the elution of the generator: 1 - Technestat Vial, 5 mL, containing 0.5 mL of 1.5 mg/mL methylparaben and 0.2 mg/mL propylparaben, sterile, non-pyrogenic 1 - Package InsertSUPPLIED SEPARATELY30 - Evacuated Collecting Vials, 30 mL, sterile, non-pyrogenic, supplied with: 90 - Radioactive Materials Labels – Collection Vial (30 en, 30 fr, 30 es) 90 - Radioactive Materials Labels – Elution Shield (30 en, 30 fr, 30 es) 1 - Package Insert30 - Generator Eluant, 0.9% sodium chloride, sterile, non-pyrogenic, available in 5, 10 mL, or 20 mL volumes, with 1 package insert. The eluant does not contain an antimicrobial agent. StorageStore generator and Sodium Pertechnetate Tc 99m solution at controlled room temperature 20-25°C (68-77°F) [see USP Controlled Room Temperature].Expiration DateThe generator should not be used after the expiration date stated on the label.The expiration time of the Sodium Pertechnetate Tc 99m solution is not later than 12 hours after time of elution. If the eluate is used to reconstitute a kit, the radiolabeled kit should not be used after 12 hours from the time of generator elution or after the expiration time stated on the labeling for the prepared drug, whichever is earlier.
Clinical Information
Chemical Structure
No Image foundClinical Pharmacology
The pertechnetate ion distributes in the body similarly to the iodide ion but is not organified when trapped in the thyroid gland. Pertechnetate concentrates in the thyroid gland, salivary glands, stomach and choroid plexus. After intravenous administration it gradually equilibrates with the extracellular space. A fraction is promptly excreted via the kidneys.
Following the administration of Sodium Pertechnetate Tc 99m as an eye drop, the drug mixes with tears within the conjunctival space. Within seconds to minutes it leaves the conjunctival space and escapes into the inferior meatus of the nose through the nasolacrimal drainage system. During this process the pertechnetate ion passes through the canaliculi, the lacrimal sac and the nasolacrimal duct. In the event of any anatomical or functional blockage of the drainage system there will be a backflow resulting in tearing (epiphora). Thus the pertechnetate escapes the conjunctival space in the tears.
While the major part of the pertechnetate escapes within a few minutes of normal drainage and tearing, it has been documented that there is some degree of transconjunctival absorption with turnover of 1.5% per minute in normal individuals, 2.1% per minute in patients without any sac and 2.7% per minute in patients with inflamed conjunctiva due to chronic dacryocystitis. Individual values may vary but these rates are probably representative and indicate that the maximum possible pertechnetate absorbed will remain below one thousandth of that used in other routine diagnostic procedures.
Non-Clinical Toxicology
None.Radiation risks associated with the use of Sodium Pertechnetate Tc 99m are greater in pediatric patients than in adults and, in general, the younger the patient the greater the risk owing to greater absorbed radiation doses and longer life expectancy. These greater risks should be taken firmly into account in all benefit risk assessments involving pediatric patients.
Long-term cumulative radiation exposure may be associated with an increased risk of cancer.
Only use generator eluant specified for use with the Ultra-Technekow V4 Generator. Do not use any other generator eluant or saline from any other source.
(The following interactions are from a published review and include reports concerning both oral and topical salicylate administration. The relationship of these interactions to the use of SALVAX is not known.)
The following alterations of laboratory tests have been reported during salicylate therapy:
Radiopharmaceuticals should be used only by physicians who are qualified by training and experience in the safe use and handling of radionuclides and whose experience and training have been approved by the appropriate government agency authorized to license the use of radionuclides.
As in the use of any radioactive material, care should be taken to minimize radiation exposure to the patient consistent with proper patient management and to ensure minimum radiation exposure to occupational workers.
After the termination of the nasolacrimal imaging procedure, blowing the nose and washing the eyes with sterile distilled water or an isotonic sodium chloride solution will further minimize the radiation dose.
Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from time of generator elution.
Allergic reactions including anaphylaxis have been reported infrequently following the administration of Sodium Pertechnetate Tc 99m.
Reference
This information is obtained from the National Institute of Health's Standard Packaging Label drug database.
"https://dailymed.nlm.nih.gov/dailymed/"
While we update our database periodically, we cannot guarantee it is always updated to the latest version.
Review
Professional
Clonazepam Description Each single-scored tablet, for oral administration, contains 0.5 mg, 1 mg, or 2 mg Clonazepam, USP, a benzodiazepine. Each tablet also contains corn starch, lactose monohydrate, magnesium stearate, microcrystalline cellulose, and povidone. Clonazepam tablets USP 0.5 mg contain Yellow D&C No. 10 Aluminum Lake. Clonazepam tablets USP 1 mg contain Yellow D&C No. 10 Aluminum Lake, as well as FD&C Blue No. 1 Aluminum Lake. Chemically, Clonazepam, USP is 5-(o-chlorophenyl)-1,3-dihydro-7-nitro-2H-1,4-benzodiazepin-2-one. It is a light yellow crystalline powder. It has the following structural formula: C15H10ClN3O3 M.W. 315.72Tips
Tips
Interactions
Interactions
A total of 440 drugs (1549 brand and generic names) are known to interact with Imbruvica (ibrutinib). 228 major drug interactions (854 brand and generic names) 210 moderate drug interactions (691 brand and generic names) 2 minor drug interactions (4 brand and generic names) Show all medications in the database that may interact with Imbruvica (ibrutinib).